EPIQ 7

Ultrasound system for breast imaging

Εύρεση παρόμοιων προϊόντων

Featuring an uncompromised level of clinical performance to meet the challenges of today's most demanding breast imaging practices.

Features
High frequency broadband imaging
High frequency broadband imaging

High frequency broadband imaging

Utilize frequencies up to 18 MHz for superb detail resolution and tissue definition of breast anatomy.

High frequency broadband imaging

High frequency broadband imaging
Utilize frequencies up to 18 MHz for superb detail resolution and tissue definition of breast anatomy.

High frequency broadband imaging

Utilize frequencies up to 18 MHz for superb detail resolution and tissue definition of breast anatomy.
Click here for more information
High frequency broadband imaging
High frequency broadband imaging

High frequency broadband imaging

Utilize frequencies up to 18 MHz for superb detail resolution and tissue definition of breast anatomy.
Advanced XRES
Advanced XRES

Advanced XRES

Adaptive imaging processing reduces speckle noise artifacts improves image clarity and margin definition allowing for better breast lesion conspicuity.

Advanced XRES

Advanced XRES
Adaptive imaging processing reduces speckle noise artifacts improves image clarity and margin definition allowing for better breast lesion conspicuity.

Advanced XRES

Adaptive imaging processing reduces speckle noise artifacts improves image clarity and margin definition allowing for better breast lesion conspicuity.
Click here for more information
Advanced XRES
Advanced XRES

Advanced XRES

Adaptive imaging processing reduces speckle noise artifacts improves image clarity and margin definition allowing for better breast lesion conspicuity.
Tissue aberration correction
Tissue aberration correction

Tissue aberration correction

User selectable speed of sound compensation maintains exceptional sharpness on fatty breast tissue.

Tissue aberration correction

Tissue aberration correction
User selectable speed of sound compensation maintains exceptional sharpness on fatty breast tissue.

Tissue aberration correction

User selectable speed of sound compensation maintains exceptional sharpness on fatty breast tissue.
Click here for more information
Tissue aberration correction
Tissue aberration correction

Tissue aberration correction

User selectable speed of sound compensation maintains exceptional sharpness on fatty breast tissue.
Anatomical Intelligence for Breast
Anatomical Intelligence for Breast

Anatomical Intelligence for Breast

Philips AI Breast is an integrated solution for whole breast ultrasound. AI Breast offers screening, diagnostic, and workflow benefits utilizing Philips unique Anatomical Intelligence. Designed with both the user and patient in mind, AI Breast allows the ultrasound scan room to be utilized for a full range of examinations without additional obtrusive hardware.

Anatomical Intelligence for Breast

Anatomical Intelligence for Breast
Philips AI Breast is an integrated solution for whole breast ultrasound. AI Breast offers screening, diagnostic, and workflow benefits utilizing Philips unique Anatomical Intelligence. Designed with both the user and patient in mind, AI Breast allows the ultrasound scan room to be utilized for a full range of examinations without additional obtrusive hardware.

Anatomical Intelligence for Breast

Philips AI Breast is an integrated solution for whole breast ultrasound. AI Breast offers screening, diagnostic, and workflow benefits utilizing Philips unique Anatomical Intelligence. Designed with both the user and patient in mind, AI Breast allows the ultrasound scan room to be utilized for a full range of examinations without additional obtrusive hardware.
Click here for more information
Anatomical Intelligence for Breast
Anatomical Intelligence for Breast

Anatomical Intelligence for Breast

Philips AI Breast is an integrated solution for whole breast ultrasound. AI Breast offers screening, diagnostic, and workflow benefits utilizing Philips unique Anatomical Intelligence. Designed with both the user and patient in mind, AI Breast allows the ultrasound scan room to be utilized for a full range of examinations without additional obtrusive hardware.
Volume Imaging
Volume Imaging

Volume Imaging

Freehand and automated volume imaging solutions allow visualization of multi-planar breast anatomy.

Volume Imaging

Volume Imaging
Freehand and automated volume imaging solutions allow visualization of multi-planar breast anatomy.

Volume Imaging

Freehand and automated volume imaging solutions allow visualization of multi-planar breast anatomy.
Click here for more information
Volume Imaging
Volume Imaging

Volume Imaging

Freehand and automated volume imaging solutions allow visualization of multi-planar breast anatomy.
Elastography
Elastography

Elastography

Breast elastography is a highly sensitive method of tracking tissue deformation requiring virtually no external compression for reproducible strain imaging results. This is the verbiage from our elastography brochure 452296267041 Nov 2010

Elastography

Elastography
Breast elastography is a highly sensitive method of tracking tissue deformation requiring virtually no external compression for reproducible strain imaging results. This is the verbiage from our elastography brochure 452296267041 Nov 2010

Elastography

Breast elastography is a highly sensitive method of tracking tissue deformation requiring virtually no external compression for reproducible strain imaging results. This is the verbiage from our elastography brochure 452296267041 Nov 2010
Click here for more information
Elastography
Elastography

Elastography

Breast elastography is a highly sensitive method of tracking tissue deformation requiring virtually no external compression for reproducible strain imaging results. This is the verbiage from our elastography brochure 452296267041 Nov 2010
Query & Retrieve
Query & Retrieve

Query & Retrieve

This feature uses multimodality query retrieval to view DICOM images such as CT, NM, MR, mammography, and Ultrasound. It gives you the ability to easily compare past and current studies without the use of an external reading station. It also allows you to eview multimodality images while live imaging, capture and append to exam for reference.

Query & Retrieve

Query & Retrieve
This feature uses multimodality query retrieval to view DICOM images such as CT, NM, MR, mammography, and Ultrasound. It gives you the ability to easily compare past and current studies without the use of an external reading station. It also allows you to eview multimodality images while live imaging, capture and append to exam for reference.

Query & Retrieve

This feature uses multimodality query retrieval to view DICOM images such as CT, NM, MR, mammography, and Ultrasound. It gives you the ability to easily compare past and current studies without the use of an external reading station. It also allows you to eview multimodality images while live imaging, capture and append to exam for reference.
Click here for more information
Query & Retrieve
Query & Retrieve

Query & Retrieve

This feature uses multimodality query retrieval to view DICOM images such as CT, NM, MR, mammography, and Ultrasound. It gives you the ability to easily compare past and current studies without the use of an external reading station. It also allows you to eview multimodality images while live imaging, capture and append to exam for reference.
Tissue Harmonics
Tissue Harmonics

Tissue Harmonics

Because both fundamental and harmonic frequencies provide important diagnostic information, THI provides superb images with fewer artifacts, particularly in cystic structures. Image contrast resolution is enhanced, and acoustic enhancement and shadowing are easily demonstrated.

Tissue Harmonics

Tissue Harmonics
Because both fundamental and harmonic frequencies provide important diagnostic information, THI provides superb images with fewer artifacts, particularly in cystic structures. Image contrast resolution is enhanced, and acoustic enhancement and shadowing are easily demonstrated.

Tissue Harmonics

Because both fundamental and harmonic frequencies provide important diagnostic information, THI provides superb images with fewer artifacts, particularly in cystic structures. Image contrast resolution is enhanced, and acoustic enhancement and shadowing are easily demonstrated.
Click here for more information
Tissue Harmonics
Tissue Harmonics

Tissue Harmonics

Because both fundamental and harmonic frequencies provide important diagnostic information, THI provides superb images with fewer artifacts, particularly in cystic structures. Image contrast resolution is enhanced, and acoustic enhancement and shadowing are easily demonstrated.
Panoramic Imaging
Panoramic Imaging

Panoramic Imaging

Using panoramic imaging, you can capture the entire landscape in a single view. It’s easy to perform, and the extend view allows a global representation of breast architecture, large masses, and multiple cysts.

Panoramic Imaging

Panoramic Imaging
Using panoramic imaging, you can capture the entire landscape in a single view. It’s easy to perform, and the extend view allows a global representation of breast architecture, large masses, and multiple cysts.

Panoramic Imaging

Using panoramic imaging, you can capture the entire landscape in a single view. It’s easy to perform, and the extend view allows a global representation of breast architecture, large masses, and multiple cysts.
Click here for more information
Panoramic Imaging
Panoramic Imaging

Panoramic Imaging

Using panoramic imaging, you can capture the entire landscape in a single view. It’s easy to perform, and the extend view allows a global representation of breast architecture, large masses, and multiple cysts.
MaxVue high definition display
MaxVue high definition display

MaxVue high definition display

At the touch of a button, MaxVue high-definition display brings extraordinary visualization of anatomy with 1,179,648 additional image pixels compared to a standard 4:3 display format mode. MaxVue enhances ultrasound viewing and provides 38% more viewing area to optimize the display of dual, side/side, biplane, and scrolling imaging modes.

MaxVue high definition display

MaxVue high definition display
At the touch of a button, MaxVue high-definition display brings extraordinary visualization of anatomy with 1,179,648 additional image pixels compared to a standard 4:3 display format mode. MaxVue enhances ultrasound viewing and provides 38% more viewing area to optimize the display of dual, side/side, biplane, and scrolling imaging modes.

MaxVue high definition display

At the touch of a button, MaxVue high-definition display brings extraordinary visualization of anatomy with 1,179,648 additional image pixels compared to a standard 4:3 display format mode. MaxVue enhances ultrasound viewing and provides 38% more viewing area to optimize the display of dual, side/side, biplane, and scrolling imaging modes.
Click here for more information
MaxVue high definition display
MaxVue high definition display

MaxVue high definition display

At the touch of a button, MaxVue high-definition display brings extraordinary visualization of anatomy with 1,179,648 additional image pixels compared to a standard 4:3 display format mode. MaxVue enhances ultrasound viewing and provides 38% more viewing area to optimize the display of dual, side/side, biplane, and scrolling imaging modes.
  • High frequency broadband imaging
  • Advanced XRES
  • Tissue aberration correction
  • Anatomical Intelligence for Breast
See all features
High frequency broadband imaging
High frequency broadband imaging

High frequency broadband imaging

Utilize frequencies up to 18 MHz for superb detail resolution and tissue definition of breast anatomy.

High frequency broadband imaging

High frequency broadband imaging
Utilize frequencies up to 18 MHz for superb detail resolution and tissue definition of breast anatomy.

High frequency broadband imaging

Utilize frequencies up to 18 MHz for superb detail resolution and tissue definition of breast anatomy.
Click here for more information
High frequency broadband imaging
High frequency broadband imaging

High frequency broadband imaging

Utilize frequencies up to 18 MHz for superb detail resolution and tissue definition of breast anatomy.
Advanced XRES
Advanced XRES

Advanced XRES

Adaptive imaging processing reduces speckle noise artifacts improves image clarity and margin definition allowing for better breast lesion conspicuity.

Advanced XRES

Advanced XRES
Adaptive imaging processing reduces speckle noise artifacts improves image clarity and margin definition allowing for better breast lesion conspicuity.

Advanced XRES

Adaptive imaging processing reduces speckle noise artifacts improves image clarity and margin definition allowing for better breast lesion conspicuity.
Click here for more information
Advanced XRES
Advanced XRES

Advanced XRES

Adaptive imaging processing reduces speckle noise artifacts improves image clarity and margin definition allowing for better breast lesion conspicuity.
Tissue aberration correction
Tissue aberration correction

Tissue aberration correction

User selectable speed of sound compensation maintains exceptional sharpness on fatty breast tissue.

Tissue aberration correction

Tissue aberration correction
User selectable speed of sound compensation maintains exceptional sharpness on fatty breast tissue.

Tissue aberration correction

User selectable speed of sound compensation maintains exceptional sharpness on fatty breast tissue.
Click here for more information
Tissue aberration correction
Tissue aberration correction

Tissue aberration correction

User selectable speed of sound compensation maintains exceptional sharpness on fatty breast tissue.
Anatomical Intelligence for Breast
Anatomical Intelligence for Breast

Anatomical Intelligence for Breast

Philips AI Breast is an integrated solution for whole breast ultrasound. AI Breast offers screening, diagnostic, and workflow benefits utilizing Philips unique Anatomical Intelligence. Designed with both the user and patient in mind, AI Breast allows the ultrasound scan room to be utilized for a full range of examinations without additional obtrusive hardware.

Anatomical Intelligence for Breast

Anatomical Intelligence for Breast
Philips AI Breast is an integrated solution for whole breast ultrasound. AI Breast offers screening, diagnostic, and workflow benefits utilizing Philips unique Anatomical Intelligence. Designed with both the user and patient in mind, AI Breast allows the ultrasound scan room to be utilized for a full range of examinations without additional obtrusive hardware.

Anatomical Intelligence for Breast

Philips AI Breast is an integrated solution for whole breast ultrasound. AI Breast offers screening, diagnostic, and workflow benefits utilizing Philips unique Anatomical Intelligence. Designed with both the user and patient in mind, AI Breast allows the ultrasound scan room to be utilized for a full range of examinations without additional obtrusive hardware.
Click here for more information
Anatomical Intelligence for Breast
Anatomical Intelligence for Breast

Anatomical Intelligence for Breast

Philips AI Breast is an integrated solution for whole breast ultrasound. AI Breast offers screening, diagnostic, and workflow benefits utilizing Philips unique Anatomical Intelligence. Designed with both the user and patient in mind, AI Breast allows the ultrasound scan room to be utilized for a full range of examinations without additional obtrusive hardware.
Volume Imaging
Volume Imaging

Volume Imaging

Freehand and automated volume imaging solutions allow visualization of multi-planar breast anatomy.

Volume Imaging

Volume Imaging
Freehand and automated volume imaging solutions allow visualization of multi-planar breast anatomy.

Volume Imaging

Freehand and automated volume imaging solutions allow visualization of multi-planar breast anatomy.
Click here for more information
Volume Imaging
Volume Imaging

Volume Imaging

Freehand and automated volume imaging solutions allow visualization of multi-planar breast anatomy.
Elastography
Elastography

Elastography

Breast elastography is a highly sensitive method of tracking tissue deformation requiring virtually no external compression for reproducible strain imaging results. This is the verbiage from our elastography brochure 452296267041 Nov 2010

Elastography

Elastography
Breast elastography is a highly sensitive method of tracking tissue deformation requiring virtually no external compression for reproducible strain imaging results. This is the verbiage from our elastography brochure 452296267041 Nov 2010

Elastography

Breast elastography is a highly sensitive method of tracking tissue deformation requiring virtually no external compression for reproducible strain imaging results. This is the verbiage from our elastography brochure 452296267041 Nov 2010
Click here for more information
Elastography
Elastography

Elastography

Breast elastography is a highly sensitive method of tracking tissue deformation requiring virtually no external compression for reproducible strain imaging results. This is the verbiage from our elastography brochure 452296267041 Nov 2010
Query & Retrieve
Query & Retrieve

Query & Retrieve

This feature uses multimodality query retrieval to view DICOM images such as CT, NM, MR, mammography, and Ultrasound. It gives you the ability to easily compare past and current studies without the use of an external reading station. It also allows you to eview multimodality images while live imaging, capture and append to exam for reference.

Query & Retrieve

Query & Retrieve
This feature uses multimodality query retrieval to view DICOM images such as CT, NM, MR, mammography, and Ultrasound. It gives you the ability to easily compare past and current studies without the use of an external reading station. It also allows you to eview multimodality images while live imaging, capture and append to exam for reference.

Query & Retrieve

This feature uses multimodality query retrieval to view DICOM images such as CT, NM, MR, mammography, and Ultrasound. It gives you the ability to easily compare past and current studies without the use of an external reading station. It also allows you to eview multimodality images while live imaging, capture and append to exam for reference.
Click here for more information
Query & Retrieve
Query & Retrieve

Query & Retrieve

This feature uses multimodality query retrieval to view DICOM images such as CT, NM, MR, mammography, and Ultrasound. It gives you the ability to easily compare past and current studies without the use of an external reading station. It also allows you to eview multimodality images while live imaging, capture and append to exam for reference.
Tissue Harmonics
Tissue Harmonics

Tissue Harmonics

Because both fundamental and harmonic frequencies provide important diagnostic information, THI provides superb images with fewer artifacts, particularly in cystic structures. Image contrast resolution is enhanced, and acoustic enhancement and shadowing are easily demonstrated.

Tissue Harmonics

Tissue Harmonics
Because both fundamental and harmonic frequencies provide important diagnostic information, THI provides superb images with fewer artifacts, particularly in cystic structures. Image contrast resolution is enhanced, and acoustic enhancement and shadowing are easily demonstrated.

Tissue Harmonics

Because both fundamental and harmonic frequencies provide important diagnostic information, THI provides superb images with fewer artifacts, particularly in cystic structures. Image contrast resolution is enhanced, and acoustic enhancement and shadowing are easily demonstrated.
Click here for more information
Tissue Harmonics
Tissue Harmonics

Tissue Harmonics

Because both fundamental and harmonic frequencies provide important diagnostic information, THI provides superb images with fewer artifacts, particularly in cystic structures. Image contrast resolution is enhanced, and acoustic enhancement and shadowing are easily demonstrated.
Panoramic Imaging
Panoramic Imaging

Panoramic Imaging

Using panoramic imaging, you can capture the entire landscape in a single view. It’s easy to perform, and the extend view allows a global representation of breast architecture, large masses, and multiple cysts.

Panoramic Imaging

Panoramic Imaging
Using panoramic imaging, you can capture the entire landscape in a single view. It’s easy to perform, and the extend view allows a global representation of breast architecture, large masses, and multiple cysts.

Panoramic Imaging

Using panoramic imaging, you can capture the entire landscape in a single view. It’s easy to perform, and the extend view allows a global representation of breast architecture, large masses, and multiple cysts.
Click here for more information
Panoramic Imaging
Panoramic Imaging

Panoramic Imaging

Using panoramic imaging, you can capture the entire landscape in a single view. It’s easy to perform, and the extend view allows a global representation of breast architecture, large masses, and multiple cysts.
MaxVue high definition display
MaxVue high definition display

MaxVue high definition display

At the touch of a button, MaxVue high-definition display brings extraordinary visualization of anatomy with 1,179,648 additional image pixels compared to a standard 4:3 display format mode. MaxVue enhances ultrasound viewing and provides 38% more viewing area to optimize the display of dual, side/side, biplane, and scrolling imaging modes.

MaxVue high definition display

MaxVue high definition display
At the touch of a button, MaxVue high-definition display brings extraordinary visualization of anatomy with 1,179,648 additional image pixels compared to a standard 4:3 display format mode. MaxVue enhances ultrasound viewing and provides 38% more viewing area to optimize the display of dual, side/side, biplane, and scrolling imaging modes.

MaxVue high definition display

At the touch of a button, MaxVue high-definition display brings extraordinary visualization of anatomy with 1,179,648 additional image pixels compared to a standard 4:3 display format mode. MaxVue enhances ultrasound viewing and provides 38% more viewing area to optimize the display of dual, side/side, biplane, and scrolling imaging modes.
Click here for more information
MaxVue high definition display
MaxVue high definition display

MaxVue high definition display

At the touch of a button, MaxVue high-definition display brings extraordinary visualization of anatomy with 1,179,648 additional image pixels compared to a standard 4:3 display format mode. MaxVue enhances ultrasound viewing and provides 38% more viewing area to optimize the display of dual, side/side, biplane, and scrolling imaging modes.

Προδιαγραφές

System dimensions
System dimensions
Width
  • 60.6 cm
Height
  • 146-171.5 cm
Depth
  • 109.2 cm
Weight
  • 104.3 kg
Control panel
Control panel
Monitor size
  • 54.6 cm
Degrees of movement
  • 180 degrees
Height adjustment
  • 25.4 cm
System dimensions
System dimensions
Width
  • 60.6 cm
Height
  • 146-171.5 cm
Control panel
Control panel
Monitor size
  • 54.6 cm
Degrees of movement
  • 180 degrees
See all specifications
System dimensions
System dimensions
Width
  • 60.6 cm
Height
  • 146-171.5 cm
Depth
  • 109.2 cm
Weight
  • 104.3 kg
Control panel
Control panel
Monitor size
  • 54.6 cm
Degrees of movement
  • 180 degrees
Height adjustment
  • 25.4 cm

You are about to visit a Philips global content page

Continue

You are about to visit a Philips global content page

Continue

Ο ιστοτοπός μας εμφανίζεται καλύτερα με την τελευταία έκδοση του Microsoft Edge, του Google Chrome ή του Firefox.