HeartStart MRx Monitor/Defibrillator for emergency care

HeartStart MRx

Monitor/Defibrillator for emergency care

Εύρεση παρόμοιων προϊόντων

Rugged, reliable, and easy-to-use, the HeartStart MRx with the DXL 12-Lead ECG algorithm, provides industry-leading patient monitoring capabilities, exceptional diagnostic measurements, proven resuscitation therapies, and CPR guidance.

Features
Built to endure, designed to evolve
Built to endure, designed to evolve

Built to endure, designed to evolve

The HeartStart MRx is built tough—tough enough to endure environmental conditions created by water, vibrations, mechanical shocks, drops, and electromagnetic activity. Plus it’s built on a scalable platform, so you can upgrade easily and take advantage of Philips advancements while retaining the same footprint and weight.
Rich clinical information, driving patient care

Rich clinical information, driving patient care

With the DXL 12-Lead ECG algorithm, the HeartStart MRx gives advanced STEMI decision support. There are predictive tools that show the probability that the patient is experiencing acute ischemia or the likely outcome of AMI. These tools help you make confident decisions to speed triage.
  • Built to endure, designed to evolve
  • Rich clinical information, driving patient care
See all features
Built to endure, designed to evolve
Built to endure, designed to evolve

Built to endure, designed to evolve

The HeartStart MRx is built tough—tough enough to endure environmental conditions created by water, vibrations, mechanical shocks, drops, and electromagnetic activity. Plus it’s built on a scalable platform, so you can upgrade easily and take advantage of Philips advancements while retaining the same footprint and weight.
Rich clinical information, driving patient care

Rich clinical information, driving patient care

With the DXL 12-Lead ECG algorithm, the HeartStart MRx gives advanced STEMI decision support. There are predictive tools that show the probability that the patient is experiencing acute ischemia or the likely outcome of AMI. These tools help you make confident decisions to speed triage.

Προδιαγραφές

Physical Dimensions
Physical Dimensions
Size with external paddles
  • 12.4" (W) x 7.7" (D) x 13.4" (H) (313 mm x 195 mm x 340 mm) "/mm
Weight
  • 13.2 lbs. (6 kg): base unit with 1 battery/pads and pads cable.
  • 13 lbs. (5.9 kg) with optional 75 mm strip chart printer.
  • Paddle tray and external standard paddles add less than 2.5 lbs. (1.1 kg).
  • Carrying case adds 4.1 lbs. (1.86 kg). lbs/kg
Defibrillation
Defibrillation
Shock Delivery
  • Via multifunction defib electrode pads or paddles
Waveform
  • Truncated Exponential Biphasic.Waveform parameters adjusted as a function of patient impedance.
Output Energy
  • Manual (selected): 1-10/15/20/30/50/70/100/120/150/170/200 Joules into a 50 Ohm load
  • AED Mode (single energy output): 150 Joules into a 50 ohm load. Joules/Ohm
Maximum Patient Impedance Range
  • 180 Ohm Ohm
Shock-to-Shock Cycle Time
  • Typically less than 20 seconds seconds
AED Mode
  • Shock advisory sensitivity and specificity meet AAMI DF-39 guidelines
Charge Time
  • Less than 5 seconds to 200 Joules with a new/ fully charged lithium ion battery at 25º C
Minimum Patient Impedance Range
  • 15 Ohm (internal defibrillation); 25 Ohm (external defibrillation) Ohm
Physical dimensions Defibrillator model HeartStart MRx (M3536A)
Physical dimensions Defibrillator model HeartStart MRx (M3536A)
Size without external paddles
  • 12.4" (W) x 7.7" (D) x 11.7" (H) (313 mm x 195 mm x 295 mm) "/mm
CPR feedback and measurement
CPR feedback and measurement
Ventilation Rate(a)
  • Target for breaths delivered before 60 seconds since last compression: 6 to 16 vpm seconds/vpm
Ventilation Volume
  • Graphic indicator: empty/one-third full/two-thirds full/full
Ventilation Rate(b)
  • Target for breaths delivered beyond 60 seconds since last compression: 9 to 16 vpm seconds/vpm
Compression Rate
  • Target: 90 to 120 cpm cpm
Compression Depth
  • Target: -1.50 to -2.00" (-38 to -51 mm) "/mm
SpO2 pulse oximetry
SpO2 pulse oximetry
Alarm Delay
  • 10 seconds
Alarm Range(b)
  • High Limit: 51 to 100% (Adult/Pediatric) %
Resolution
  • 0,01%
Alarm Range(a)
  • Low Limit: 50 to 99% (Adult/Pediatric) %
Range
  • 0 to 100% %
ECG and arrhythmia monitoring
ECG and arrhythmia monitoring
Lead Fault
  • ‘Lead Off ’ message and dashed line displayed if an electrode or lead wire becomes disconnected.
Heart Rate/Arrhythmia Alarms
  • HR/Asystole/VFIB/VTACH/VTACH/extreme tachycardia/extreme bradycardia/PVC rate.
ECG Size
  • 2.5/5/10/20/40 mm/mV autogain mm/mV
Pads Fault
  • Dashed line displayed if a pad becomes disconnected.
Input
  • Up to 4 ECG waves displayed and up to 3 ECG waves print simultaneously.
Leads
  • Lead I, II, or III obtained through 3-lead ECG cable and separate monitoring electrodes.
  • With 5-lead cable, obtain leads I/II/III/aVR/aVL/ aVF or V.
  • Pads ECG obtained through 2 multifunction defibrillation electrode pads.
Heart Rate Display
  • Digital readout on display 15 to 300 bpm with accuracy ±10% bpm/%
Noninvasive Blood Pressure
Noninvasive Blood Pressure
Maximum Pressure
  • 280 mmHg mmHg
Waveform
  • Monophasic Truncated Exponential
Alarm Range(g)
  • Diastolic low limit: 10 - 240 (Adult) and 10 - 145 (Pediatric)
Refractory Period
  • 340 msec (30 to 80 ppm); 240 msec (90 to 180 ppm) msec/ppm
Alarm Range(e)
  • Systolic low limit: 30 - 265 (Adult) and 30 - 175 (Pediatric)
Pressure Range(b)
  • Diastolic: 20 to 200 mmHg mmHg
Initial Pressure
  • Adult: 160 mmHg and Pediatric: 120 mmHg mmHg
Alarm Range(d)
  • Systolic high limit: 30 - 270 (Adult) and 35 - 180 (Pediatric)
Current Pulse Amplitude
  • 10 mA to 160 mA (5 mA resolution); accuracy 10 mA to 50 mA ± 5 mA, 50 mA - 160 m A ± 10% mA
Rate
  • 30 ppm to 180 ppm (10 ppm increments); accuracy ± 1.5% ppm
Pulse Width
  • 40 ms with ± 10% accuracy ms/%
Modes
  • Demand or Fixed Rate
Alarm Range(f)
  • Diastolic high limit: 18 - 240 (Adult) and 18 - 150 (Pediatric)
Pressure Range(a)
  • Systolic: 40 to 260 mmHg mmHg
Environmental & physical requirements
Environmental & physical requirements
Operating vibration
  • MIL STD 810E 514.4 Category 6 Helicopter
General storage vibration
  • UH60 Non-Operating: IEC 68-2-6 Swept Sine Vibration and IEC 68-2-64 Random Vibration
Storage temperature
  • -20 - 70º C (-4º - 158º F) ° C/° F
Operating altitude
  • 0 to 15000 ft (0 to 4500 m) ft/m
Mechanical shock
  • Bump: IEC 68-2-29
  • Freefall: IEC 68-2-32
Safety
  • Meets EN 60601-1, UL 2601-1/CSA C22.2 No. 601-1
Solids/Water resistance
  • IP24
Storage altitude
  • 0 to 15000 ft (0 to 4500 m) ft/m
Operating humidity
  • 0% to 95% relative %
Operating temperature
  • 0º - 45º C (32º - 113º F) ° C/° F
Strip Chart Recorder
Strip Chart Recorder
Reports
  • Event Summary, 12-Lead/Operational Check/ Configuration/Status Log and Device Information
Paper Size
  • 1.97” (50 mm) W by 100 ft. (30 m) L and 2.95” (75 mm) W by 100 ft. (30 m) L "/ft/mm/m
Recorder(a)
  • Standard: 50 mm (paper width) thermal array printer mm
Recorder(b)
  • Optional: 75 mm (paper width) thermal array printer mm
Auto Printing
  • Recorder can be configured to print marked events/charge/ shock and alarms
Continuous ECG Strip
  • Prints primary ECG lead with event annotations and measurements in real-time or with 10-second delay
Battery
Battery
Dimensions
  • 6.5" (H) x 3.8" (W) x 1.6" (D) (165 mm x 95 mm x 42 mm) "/mm
Capacity(b)
  • At least 3.5 hours of continuous 12-lead ECG/SpO2 and CO2 monitoring.
  • With NBP every 15 minutes and pacing at 180 ppm at 160 mA on one new fully charged battery. hours
Type
  • 6.3 Ah, 14.8 V, rechargeable lithium ion Ah/V
Charge Time
  • Approximately 3 hours from fully depleted to 100%. 90 minutes from fully depleted to 80% hours/%
Capacity(a)
  • At least 5 hours of continuous 12-lead ECG/SpO2 and CO2 monitoring.
  • With NBP every 15 minutes on one new fully charged battery. hours
Weight
  • 1.6 lb. (0.73 kg) lb/kg
Display
Display
Dimensions
  • 8.4’’ diagonal (128 mm x 171 mm) "/mm
Wave Viewing Time
  • 5 seconds (ECG) seconds
Resolution
  • 480 x 640 pixels (VGA) VGA
Type
  • TFT color LCD
12-Lead ECG
12-Lead ECG
Input
  • 12-Lead cable: leads I/II/III/aVR/aVL/ aVF and V/C1-V/C6
Display View
  • All 12-lead ECG waves display simultaneously
Transmission
  • CompactFlash data card; Bluetooth® dial-up Internet connection, Bluetooth® FTP
Strip Recorder
  • All 12-leads print on the strip chart printer in 3x4 format
End-tidal CO2
End-tidal CO2
Alarm Range(h)
  • Low Limit: 10 to 95 mmHg (Adult/Pediatric) mmHg
Sample Size
  • 50 ml per minute ml
Resolution
  • 1 mmHg (0.1 kPa) mmHg/kPa
Alarm Range(i)
  • High Limit: 20 to 100 mmHg (Adult/Pediatric) mmHg
Range
  • 0 to 99 mmHg mmHg
Data storage
Data storage
Data Card
  • 12 hours of continuous ECG waveforms and events.
  • Plus 50 12-lead ECG reports on a CompactFlash memory card
Internal
  • 12 hours of continuous ECG waveforms and events. Plus 50 12-lead ECG reports
Physical Dimensions
Physical Dimensions
Size with external paddles
  • 12.4" (W) x 7.7" (D) x 13.4" (H) (313 mm x 195 mm x 340 mm) "/mm
Weight
  • 13.2 lbs. (6 kg): base unit with 1 battery/pads and pads cable.
  • 13 lbs. (5.9 kg) with optional 75 mm strip chart printer.
  • Paddle tray and external standard paddles add less than 2.5 lbs. (1.1 kg).
  • Carrying case adds 4.1 lbs. (1.86 kg). lbs/kg
Defibrillation
Defibrillation
Shock Delivery
  • Via multifunction defib electrode pads or paddles
Waveform
  • Truncated Exponential Biphasic.Waveform parameters adjusted as a function of patient impedance.
See all specifications
Physical Dimensions
Physical Dimensions
Size with external paddles
  • 12.4" (W) x 7.7" (D) x 13.4" (H) (313 mm x 195 mm x 340 mm) "/mm
Weight
  • 13.2 lbs. (6 kg): base unit with 1 battery/pads and pads cable.
  • 13 lbs. (5.9 kg) with optional 75 mm strip chart printer.
  • Paddle tray and external standard paddles add less than 2.5 lbs. (1.1 kg).
  • Carrying case adds 4.1 lbs. (1.86 kg). lbs/kg
Defibrillation
Defibrillation
Shock Delivery
  • Via multifunction defib electrode pads or paddles
Waveform
  • Truncated Exponential Biphasic.Waveform parameters adjusted as a function of patient impedance.
Output Energy
  • Manual (selected): 1-10/15/20/30/50/70/100/120/150/170/200 Joules into a 50 Ohm load
  • AED Mode (single energy output): 150 Joules into a 50 ohm load. Joules/Ohm
Maximum Patient Impedance Range
  • 180 Ohm Ohm
Shock-to-Shock Cycle Time
  • Typically less than 20 seconds seconds
AED Mode
  • Shock advisory sensitivity and specificity meet AAMI DF-39 guidelines
Charge Time
  • Less than 5 seconds to 200 Joules with a new/ fully charged lithium ion battery at 25º C
Minimum Patient Impedance Range
  • 15 Ohm (internal defibrillation); 25 Ohm (external defibrillation) Ohm
Physical dimensions Defibrillator model HeartStart MRx (M3536A)
Physical dimensions Defibrillator model HeartStart MRx (M3536A)
Size without external paddles
  • 12.4" (W) x 7.7" (D) x 11.7" (H) (313 mm x 195 mm x 295 mm) "/mm
CPR feedback and measurement
CPR feedback and measurement
Ventilation Rate(a)
  • Target for breaths delivered before 60 seconds since last compression: 6 to 16 vpm seconds/vpm
Ventilation Volume
  • Graphic indicator: empty/one-third full/two-thirds full/full
Ventilation Rate(b)
  • Target for breaths delivered beyond 60 seconds since last compression: 9 to 16 vpm seconds/vpm
Compression Rate
  • Target: 90 to 120 cpm cpm
Compression Depth
  • Target: -1.50 to -2.00" (-38 to -51 mm) "/mm
SpO2 pulse oximetry
SpO2 pulse oximetry
Alarm Delay
  • 10 seconds
Alarm Range(b)
  • High Limit: 51 to 100% (Adult/Pediatric) %
Resolution
  • 0,01%
Alarm Range(a)
  • Low Limit: 50 to 99% (Adult/Pediatric) %
Range
  • 0 to 100% %
ECG and arrhythmia monitoring
ECG and arrhythmia monitoring
Lead Fault
  • ‘Lead Off ’ message and dashed line displayed if an electrode or lead wire becomes disconnected.
Heart Rate/Arrhythmia Alarms
  • HR/Asystole/VFIB/VTACH/VTACH/extreme tachycardia/extreme bradycardia/PVC rate.
ECG Size
  • 2.5/5/10/20/40 mm/mV autogain mm/mV
Pads Fault
  • Dashed line displayed if a pad becomes disconnected.
Input
  • Up to 4 ECG waves displayed and up to 3 ECG waves print simultaneously.
Leads
  • Lead I, II, or III obtained through 3-lead ECG cable and separate monitoring electrodes.
  • With 5-lead cable, obtain leads I/II/III/aVR/aVL/ aVF or V.
  • Pads ECG obtained through 2 multifunction defibrillation electrode pads.
Heart Rate Display
  • Digital readout on display 15 to 300 bpm with accuracy ±10% bpm/%
Noninvasive Blood Pressure
Noninvasive Blood Pressure
Maximum Pressure
  • 280 mmHg mmHg
Waveform
  • Monophasic Truncated Exponential
Alarm Range(g)
  • Diastolic low limit: 10 - 240 (Adult) and 10 - 145 (Pediatric)
Refractory Period
  • 340 msec (30 to 80 ppm); 240 msec (90 to 180 ppm) msec/ppm
Alarm Range(e)
  • Systolic low limit: 30 - 265 (Adult) and 30 - 175 (Pediatric)
Pressure Range(b)
  • Diastolic: 20 to 200 mmHg mmHg
Initial Pressure
  • Adult: 160 mmHg and Pediatric: 120 mmHg mmHg
Alarm Range(d)
  • Systolic high limit: 30 - 270 (Adult) and 35 - 180 (Pediatric)
Current Pulse Amplitude
  • 10 mA to 160 mA (5 mA resolution); accuracy 10 mA to 50 mA ± 5 mA, 50 mA - 160 m A ± 10% mA
Rate
  • 30 ppm to 180 ppm (10 ppm increments); accuracy ± 1.5% ppm
Pulse Width
  • 40 ms with ± 10% accuracy ms/%
Modes
  • Demand or Fixed Rate
Alarm Range(f)
  • Diastolic high limit: 18 - 240 (Adult) and 18 - 150 (Pediatric)
Pressure Range(a)
  • Systolic: 40 to 260 mmHg mmHg
Environmental & physical requirements
Environmental & physical requirements
Operating vibration
  • MIL STD 810E 514.4 Category 6 Helicopter
General storage vibration
  • UH60 Non-Operating: IEC 68-2-6 Swept Sine Vibration and IEC 68-2-64 Random Vibration
Storage temperature
  • -20 - 70º C (-4º - 158º F) ° C/° F
Operating altitude
  • 0 to 15000 ft (0 to 4500 m) ft/m
Mechanical shock
  • Bump: IEC 68-2-29
  • Freefall: IEC 68-2-32
Safety
  • Meets EN 60601-1, UL 2601-1/CSA C22.2 No. 601-1
Solids/Water resistance
  • IP24
Storage altitude
  • 0 to 15000 ft (0 to 4500 m) ft/m
Operating humidity
  • 0% to 95% relative %
Operating temperature
  • 0º - 45º C (32º - 113º F) ° C/° F
Strip Chart Recorder
Strip Chart Recorder
Reports
  • Event Summary, 12-Lead/Operational Check/ Configuration/Status Log and Device Information
Paper Size
  • 1.97” (50 mm) W by 100 ft. (30 m) L and 2.95” (75 mm) W by 100 ft. (30 m) L "/ft/mm/m
Recorder(a)
  • Standard: 50 mm (paper width) thermal array printer mm
Recorder(b)
  • Optional: 75 mm (paper width) thermal array printer mm
Auto Printing
  • Recorder can be configured to print marked events/charge/ shock and alarms
Continuous ECG Strip
  • Prints primary ECG lead with event annotations and measurements in real-time or with 10-second delay
Battery
Battery
Dimensions
  • 6.5" (H) x 3.8" (W) x 1.6" (D) (165 mm x 95 mm x 42 mm) "/mm
Capacity(b)
  • At least 3.5 hours of continuous 12-lead ECG/SpO2 and CO2 monitoring.
  • With NBP every 15 minutes and pacing at 180 ppm at 160 mA on one new fully charged battery. hours
Type
  • 6.3 Ah, 14.8 V, rechargeable lithium ion Ah/V
Charge Time
  • Approximately 3 hours from fully depleted to 100%. 90 minutes from fully depleted to 80% hours/%
Capacity(a)
  • At least 5 hours of continuous 12-lead ECG/SpO2 and CO2 monitoring.
  • With NBP every 15 minutes on one new fully charged battery. hours
Weight
  • 1.6 lb. (0.73 kg) lb/kg
Display
Display
Dimensions
  • 8.4’’ diagonal (128 mm x 171 mm) "/mm
Wave Viewing Time
  • 5 seconds (ECG) seconds
Resolution
  • 480 x 640 pixels (VGA) VGA
Type
  • TFT color LCD
12-Lead ECG
12-Lead ECG
Input
  • 12-Lead cable: leads I/II/III/aVR/aVL/ aVF and V/C1-V/C6
Display View
  • All 12-lead ECG waves display simultaneously
Transmission
  • CompactFlash data card; Bluetooth® dial-up Internet connection, Bluetooth® FTP
Strip Recorder
  • All 12-leads print on the strip chart printer in 3x4 format
End-tidal CO2
End-tidal CO2
Alarm Range(h)
  • Low Limit: 10 to 95 mmHg (Adult/Pediatric) mmHg
Sample Size
  • 50 ml per minute ml
Resolution
  • 1 mmHg (0.1 kPa) mmHg/kPa
Alarm Range(i)
  • High Limit: 20 to 100 mmHg (Adult/Pediatric) mmHg
Range
  • 0 to 99 mmHg mmHg
Data storage
Data storage
Data Card
  • 12 hours of continuous ECG waveforms and events.
  • Plus 50 12-lead ECG reports on a CompactFlash memory card
Internal
  • 12 hours of continuous ECG waveforms and events. Plus 50 12-lead ECG reports